Application Sectional Matrices


O-Shape

Die Zahn-Matrize wird gespannt und vom Tablett genommen                                            


The selected WALSER® Matrix must be pointing in an occlusal direction, and it is from this side that the forceps are applied. Spread out the WALSER Matrix Forceps to the point where the first notches on the tip of the forceps engage in the recesses of the matrix springs.

Mit der Matrizenzange die Zahn-Matrize spannen und über den Zahn stülpen  


Slip the matrix over the tooth and insert in the interdental spaces. Relax the forceps when the papilla is reached. The strips will then wrap around the neck of the tooth. Then shift the matrix accordingly in an occlusal direction.


Setzen Sie die Zahn-Matrize O-Form ein, die mit einer Handbewegung automatisch am Zahn anliegt  


Once the tooth filling has been placed then retension the matrix to maximum point. This is important so as not to damage the well contoured filling.

Before removing the matrix it should be moved by a gentle rocking motion around the sagittal axis, as this will release the strips more easily from the filling material.


 

X-Shape 

   
Die Zahn-Matrize X-Form wird ganz aufgespannt  


The selected WALSER® Matrix must be pointing in an occlusal direction, and it is from this side that the forceps are applied. Spread out the WALSER Matrix Forceps to the point where the first notches on the tip of the forceps engage in the recesses of the matrix springs.

Legen sie einfach und schnell zwei Füllungen gleichzeitig  

 

Insert the matrix between the interdental space. Relax the forceps when the papilla is reached. The strips will then wrap around the neck of the tooth. Then shift the matrix accordingly in an occlusal direction.


Legen auch Sie zwei Füllungen gleichzeitig mit der Zahn-Matrize die sich auch für Kinder hervorragend eignet  


Once the tooth filling has been placed then retension the matrix to maximum point. This is important so as not to damage the well contoured filling.

Before removing the matrix it should be moved by a gentle rocking motion around the sagittal axis, as this will release the strips more easily from the filling material.

 


ON-Shape

Setzen Sie die einzigartige Zahn-Matrize ein, die disto-zervikal automatisch anliegt                                            

The selected WALSER® Matrix must be pointing in an occlusal direction, and it is from this side that the forceps are applied. Spread out the WALSER Matrix Forceps to the point where the first notches on the tip of the forceps engage in the recesses of the matrix springs.

Mit nur einer Handbewegung liegt die Zahn-Matrize disto-zervikal an  

Slip the matrix over the tooth and insert in the interdental spaces. Relax the forceps when the papilla is reached. The strips will then wrap around the neck of the tooth. Then shift the matrix accordingly in an occlusal direction.

It fits disto-cervical automatically, comfortably placed in seconds with one hand movement, prevents over-stuffing and saves you from the grinding away of surplus.

Die Walser Zahn-Matrize spannt sich automatisch um den Zahn wie ein Korsett  

Once the tooth filling has been placed then retension the matrix to maximum point. This is important so as not to damage the well contoured filling.

Before removing the matrix it should be moved by a gentle rocking motion around the sagittal axis, as this will release the strips more easily from the filling material.

 

XF-Shape

   
Spannen Sie die Zahn-Matrize XF-Form mit nur einer Handbewegung und sparen Sie viel Zeit und Geld  

The selected WALSER® Matrix must be pointing in an occlusal direction, and it is from this side that the forceps are applied. Spread out the WALSER Matrix Forceps to the point where the first notches on the tip of the forceps engage in the recesses of the matrix springs.

Mit der Zahn-Matrize für Frontzähne legen Sie schnell und einfach Zahnfüllungen  

The cavity must be filled to the point of overflow. Insert the tensioned matrix an release. The spring on which the number is apllied should be positioned labially.  

Sparen Sie Zeit und Geld mit der Zahn-Matrize für Frontzähne  

Once the tooth filling has been placed then retension the matrix to maximum point, pull in a labial direction and angle downward slightly. Then pull in a palatinal direction and angle down. Repeat the procedure if necessary. There is no cervical excess after the WALSER® front matrix has been removed, and the thin thread from pressing can be easily removed.